吸引器连接管联合胃镜可视性清除血凝块装置在上消化道大出血中的应用
DOI:
作者:
作者单位:

1.武汉科技大学医学部医学院;2.中部战区总医院消化内科

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金(82200708);湖北省自然科学基金(2021CFB001);湖北省卫健委面上科研项目(WJ2023M092)


Application of suction connecting tube combined with gastroscopy visual blood clot removal device in upper gastrointestinal bleeding
Author:
Affiliation:

1.School of Medicine, Wuhan University of Science and Technology;2.Department of Gastroenterology, General Hospital of Central Theater Command

Fund Project:

National Natural Science Foundation of China (82200708);Natural Science Foundation of Hubei Province of China (2021CFB001);Health Commission of Hubei Province Scientific Research Project (WJ2023M092)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 文章评论
    摘要:

    目的 探究吸引器连接管联合胃镜可视性清除血凝块装置在上消化道大出血患者血凝块清除术中的应用价值。方法 回顾性收集2023年1月至2024年6月作者单位收治的上消化道大出血患者临床资料共18例,术中应用吸引器连接管联合胃镜清除消化道内血液及血凝块,观察治疗效果。结果 18例患者应用装置的操作时间为4~16min,平均8.2±3.1min。清除血凝块及血液总量为120~500ml,平均221.1±97.1ml。17例患者均一次性清除血液及血凝块,并有效行止血治疗,成功率为94.4%;1例胃癌并出血患者,内镜下无法止血治疗,后续行外科手术治疗。所有患者均未出现严重并发症。结论 吸引器连接管联合胃镜可视性清除血凝块装置可高效清除消化道内血凝块及血液,极大改善视野,提高止血成功率,临床价值高,值得推广应用。

    Abstract:

    Objective To explore the application value of a suction connecting tube combined with gastroscopy visual blood clot removal device in blood clot removal surgery for patients with upper gastrointestinal bleeding. Methods The clinical data of 18 patients with upper gastrointestinal bleeding treated in the author’s hospital from January 2023 to June 2024 were retrospectively analyzed. During the operation, a suction connecting tube combined with gastroscopy device was used to remove blood and blood clots from the digestive tract, and the treatment effect was observed. Results The operating time of the device for 18 patients ranged from 4 to 16 minutes, with an average of 8.2±3.1 minutes. The clearance of blood clots and total blood volume is 120 to 500ml, with an average of 221.1 ± 97.1ml. 17 patients completed the removal of blood and blood clots at one time, and effectively received hemostatic treatment, with a success rate of 94.4%; A patient with gastric cancer and bleeding, Endoscopic treatment was unable to stop the bleeding, and subsequent surgical treatment was performed. All patients did not experience serious complications. Conclusion The suction connecting tube combined with gastroscopy visual blood clot removal device can efficiently remove blood clots and blood in the digestive tract, greatly improve the field of view, and increase the success rate of hemostasis. It has high clinical value and is worthy of promotion and application.

    参考文献
    相似文献
    引证文献
引用本文

程俊,张俊君,张松,等.吸引器连接管联合胃镜可视性清除血凝块装置在上消化道大出血中的应用[J].中华消化内镜杂志,,().

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-08-21
  • 最后修改日期:2024-10-13
  • 录用日期:2024-11-12
  • 在线发布日期:
  • 出版日期:
您是第位访问者

通信地址:南京市鼓楼区紫竹林3号《中华消化内镜杂志》编辑部   邮编:210003

中华消化内镜杂志 ® 2025 版权所有
技术支持:北京勤云科技发展有限公司